High-density 400GE/100GE ports, supporting high-bandwidth and large-capacity server access
The RG-S6580-48CQ8QC is a high-density access switch and provides various ports within the space of 1 RU. With improved data forwarding capabilities, it can be flexibly deployed and supports access of 100G servers. It can evolve to 100GE/400GE data centers.
1+1 power modules, hot swapping, and service failover within seconds, ensuing service continuity
System Specifications |
RG-S6580-48CQ8QC |
|
Ports |
48 × 100GE ports (DSFP) + 8 × 400GE ports (QSFP-DD) |
|
Expansion Modules |
Not supported |
|
Expansion Module Slots |
Two power supply module slots (1+1 redundancy) Six fan module slots (5+1 redundancy; at least 5 fan modules are required) |
|
Management Port |
One management port, one console port, and one USB port, compliant with the USB2.0 standard |
|
Switching Capacity |
16.0 Tbps |
|
Packet Forwarding Rate |
5350 Mpps |
|
802.1Q VLAN |
4094 |
|
Dimensions |
RG-S6580-48CQ8QC |
|
Dimensions (W × D × H) |
442 mm x 700 mm x 44 mm (17.40 in. x 27.56 in. x 1.73 in., 1 RU) |
|
Weight |
Chassis with six fan modules and two power supply modules: 11.5 kg (25.35 lbs.) |
|
Power Supply and Consumption |
RG-S6580-48CQ8QC |
|
Power Input |
AC input RG-PA1200I-F module ● Rated voltage: 110 V AC/220 V AC ● Rated voltage range: 100 V AC to 127 V AC (50 Hz to 60 Hz), rated current: 13.8 A ● Rated voltage range: 200 V AC to 240 V AC (50 Hz to 60 Hz), rated current: 8.5 A ● Max voltage range: 90 V AC to 264 V AC (47 Hz to 63 Hz)
HVDC input RG-PA1200I-F module ● Rated voltage: 240 V DC ● Max voltage range: 180 V DC to 300 V DC ● Max input current: 6.5 A |
|
Maximum Power Consumption |
● Max: 742 W ● Typical: 633 W ● Static: 178 W |
|
Environment and Reliability |
RG-S6580-48CQ8QC |
|
Temperature Alarm |
Temperature alarms and overheat protection |
|
Operating Temperature |
0ºC to 40ºC (32ºF to 104ºF) |
|
Storage Temperature |
–40°C to +70°C (–40ºF to +158ºF) |
|
Operating Humidity |
10% RH to 90% RH (non-condensing) |
|
Storage humidity |
5% to 95% RH (non-condensing) |
|
Working altitude |
Operating altitude: up to 5000 m (16,404.20 ft.) Storage altitude: up to 5000 m (16,404.20 ft.) |