Full Gigabit Ethernet Access Switch for Large-sized Networks
Full-gigabit access switch for large-sized enterprise and campus LANs, with four 10G uplink optical ports for high-speed data transmission 48 x 1000 Mbps Ethernet ports with auto-negotiation, providing high-speed network experience for short-distance services
Hot-swappable dual power modules are provided for 1+1 power redundancy. Seamless power module failover can be realized if one power module fails, providing dual protection for links
Hardware Specifications |
RG-S5310-48GT4XS-E |
Interface Specifications |
|
Fixed port |
48 x 10/100/1000 BASE-T ports 4 x 1G/10G SFP+ ports |
Power module |
2 x power modules (1+1 redundancy of power modules) |
Management port |
1 x MGMT port, 1 x console port, and 1 x USB 2.0 port |
System Specifications |
|
Switching Capacity |
176 Gbps |
Packet Forwarding Rate |
132 Mpps |
Number of MAC addresses |
32,000 |
ARP table size |
4k/16k (authorized) |
ND table size |
2k/8k (authorized) |
Number of IPv4 unicast routes |
8k/12k (authorized) |
Number of IPv4 multicast routes |
2,500 |
Number of IPv6 unicast routes |
4,000 |
Number of IPv6 multicast routes |
1,200 |
Number of ACEs |
Ingress: 3,500 Egress: 1,500 |
Number of IGMP groups |
2,500 |
Number of MLD groups |
1,000 |
Number of VSU members |
8 |
Dimensions and Weight |
|
Dimensions (W x D x H) |
442 mm x 420 mm x 43.6 mm (17.40 in. x 16.56 in. x 1.72 in.), 1 RU |
Weight |
4.3 kg (9.48 lbs) |
CPU and Storage |
|
CPU |
1.2 GHz dual-core processor |
BOOTROM |
16 MB |
Flash |
2 GB |
SDRAM |
1 GB |
Power and Consumption |
|
Maximum power consumption |
≤ 55 W |
Maximum output power |
RG-PA70IB: 70 W RG-PA150IB-F: 150 W RG-PD150IB-F: 150 W |
Rated input voltage |
RG-PA70IB: 100 V AC to 240 V AC RG-PA150IB-F: 100 V AC to 240 V AC RG-PD150IB-F: -48 V DC to -60 V DC |
Maximum input voltage |
RG-PA70IB: 90 V AC to 264 V AC, 50 Hz to 60 Hz RG-PA150IB-F: 90 V AC to 264 V AC, 50 Hz to 60 Hz RG-PD150IB-F: -36 V DC to -75 V DC |
Environment and Reliability |
|
MTBF |
40.03 years (dual power modules) 23.53 years (single power module) |
Primary airflow |
Left/Front-to-rear airflow |
Operating temperature |
0°C to 45°C (32°F to 113°F) |
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
Operating humidity |
10% to 90% RH (non-condensing) |
Storage humidity |
5% to 95% RH (non-condensing) |
Operating altitude |
0 m to 5000 m (16404.20 ft.) |
Operating noise |
< 52.4 dB |
Interface surge protection |
Power port: 6 kV Telecom port: 10 kV (MGMT port: 4 kV) |
Reviews (0)