Fit for data centers, MANs, campus networks, and scenarios with data centers and campus networks
Up to 52 x 10GE ports and 12 x 100GE ports per line card, and up to 416 x 10GE ports and 96 x 100GE ports per switch Fit for data centers, MANs, campus networks, and scenarios with data centers and campus networks
Special optical port protection and separate optical port power supply design, isolating a faulty module without affecting services on other ports Rapid service restartion on the corresponding port after the faulty module is replaced
Hardware Specifications |
N18010-E |
|
Interface Specifications |
||
Power module |
4 |
|
Fan module |
2 |
|
Fixed management port |
1 x MGMT port, 1 x console port, and 1 x USB port |
|
Supervisor module slot |
2 |
|
Line card slot |
8 |
|
Switch fabric module slot |
4 |
|
System Specifications |
||
Packet forwarding rate |
14,200 Mpps |
|
System switching capacity |
19.2 Tbps |
|
Number of MAC address |
● Number of static MAC addresses XA card: 4,000 XB card: 10,000 ● Number of global MAC addresses XA card: 96,000 XB card: 256,000 |
|
ARP table size |
XA card: 40,000 XB card: 96,000 |
|
Number of IPv4 unicast routes |
XA card: 64,000 (shared with IPv6 routes) XB card: 350,000 (shared with IPv6 routes) |
|
Number of IPv4 multicast routes |
XA card: 4,000 XB card: 4,000 |
|
Number of IPv6 unicast routes |
XA card: 15,000 (≤ 64 bytes, shared with IPv4 routes) XB card: 65,000 |
|
Number of IPv6 multicast routes |
XA card: 2,000 XB card: 2,000) |
|
Number of ACEs |
● XA card: Ingress: 7,000 Egress: 1,500 ● XA card: Ingress: 28,000 Egress: 4,000 |
|
Number of VSU members |
2 |
|
Dimensions and Weight |
||
Dimensions (W x D x H) |
442.5 x 560 x 442 mm (17.42 in. x 22.05 in. x 17.40 in.), 10 RU |
|
Weight (empty chassis and fan modules) |
43.6 kg (96.12 lbs) |
|
CPU and Storage |
||
CPU |
Supervisor module: M18000E-CM : 2.2 GHz quad-core processor Line card: XA/XB/FE card: 2.2 GHz quad-core processor |
|
Storage |
Supervisor module and line card: Flash memory: 8 GB SDRAM: DDR4 4 GB |
|
Power and Consumption |
||
Maximum power consumption |
M18000E-CM: 60 W M18000E-48GT4XS-XA: 85 W M18000E-48SFP4XS-XA: 117 W M18000E-24GT8SFP8XS-XA: 95 W M18000E-32XS-XB: 149 W M18000E-52XS-XB: 250 W M18000E-12CQ-XB:240 W M18010E-FE-X I: 50 W M18000E-FE-X II: 160 W M10C-FAN: 216 W |
|
Maximum output power |
RG-PA600I: 600 W RG-PD600I: 600 W RG-PA1600I: ● 90 to 180 V AC; 1,200 W ● 180 to 264 V AC; power: 1,600 W RG-PD1600I: 1,400 W |
|
Rated input voltage |
● RG-PA600I: 100–120 V, 200–240 V, 50/60 Hz ● RG-PD600I: –48 V DC ● RG-PA1600I: 100–120V, 200–240 V, 50/60 Hz ● RG-PD1600I: –48 V DC |
|
Maximum input voltage |
● RG-PA600I: 90–264 V, 47–63 Hz ● RG-PD600I: –40 V DC to –75 V DC ● RG-PA1600I: 90–264 V, 47–63 Hz ● RG-PD1600I: –40 V DC to –75 V DC |
|
Environment and Reliability |
||
MTBF |
≥ 200,000 hours |
|
Primary airflow |
Line card: Side-to-rear airflow Supervisor module/FE: Front-to-rear airflow |
|
Operating temperature |
0°C to 50°C (37°F to 122°F) |
|
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
|
Operating humidity |
10% to 90% RH (non-condensing) |
|
Storage humidity |
5% to 95% RH (non-condensing) |
|
Operating noise |
55.9 dB at the temperature of 35°C (95°F) 73.4 dB at the temperature of 50°C (122°F) |
|
Interface surge protection |
Power port: 6 kV Telecom port: 4 kV (MGMT port) |
|
Operating altitude |
–500 m to +5,000 m (–1640.42 ft. to +16404.20 ft.) |