200GE access switch (one 200GE port split into two 100GE ports), and 400GE ZR/ZR+ optical modules for interconnection at the maximum distance of 120 km
Data center 200GE access switch with 1 RU, various ports, improved data forwarding capability, and flexible scenario deployment200GE/100GE server access and evolution to 100GE/400GE data center networks
Power modules in 1+1 redundancy mode, failover in seconds, and power module replacement without network interruption, providing double protection for links
System Specifications |
RG-S6580-24DC8QC |
|
Ports |
24 × 200GE ports (QSFP56) + 8 × 400GE ports (QSFP-DD) |
|
Expansion Modules |
Not supported |
|
Expansion Module Slots |
Two power supply module slots (1+1 redundancy) Six fan module slots (5+1 redundancy; at least 5 fan modules are required) |
|
Management Port |
One management port, one console port, and one USB port, compliant with the USB2.0 standard |
|
Switching Capacity |
16.0 Tbps |
|
Packet Forwarding Rate |
5350 Mpps |
|
802.1Q VLAN |
4094 |
|
Dimensions |
RG-S6580-24DC8QC |
|
Dimensions (W × D × H) |
442 mm x 670.8 mm x 43.6 mm (17.40 in. x 26.41 in. x 1.72 in., 1 RU) |
|
Weight |
Chassis with six fan modules and two power supply modules: 11 kg (24.25 lbs.) |
|
Power Supply and Consumption |
RG-S6580-24DC8QC |
|
Power Input |
AC input RG-PA1200I-F module ● Rated voltage: 110 V AC/220 V AC ● Rated voltage range: 100 V AC to 127 V AC (50 Hz to 60 Hz), rated current: 13.8 A ● Rated voltage range: 200 V AC to 240 V AC (50 Hz to 60 Hz), rated current: 8.5 A ● Max voltage range: 90 V AC to 264 V AC (47 Hz to 63 Hz)
HVDC input RG-PA1200I-F module ● Rated voltage: 240 V DC ● Max voltage range: 180 V DC to 300 V DC ● Max input current: 6.5 A |
|
Maximum Power Consumption |
● Max: 850 W ● Typical: 700 W ● Static: 300 W |
|
Environment and Reliability |
RG-S6580-24DC8QC |
|
Temperature Alarm |
Temperature alarms and overheat protection |
|
Operating Temperature |
0ºC to 40ºC (32ºF to 104ºF) |
|
Storage Temperature |
–40°C to +70°C (–40ºF to +158ºF) |
|
Operating Humidity |
10% RH to 90% RH (non-condensing) |
|
Storage humidity |
5% to 95% RH (non-condensing) |
|
Working altitude |
Operating altitude: up to 5000 m (16,404.20 ft.) Storage altitude: up to 5000 m (16,404.20 ft.) |