Can be deployed in data centers, metropolis area networks, campus networks, or integrated scenarios of data centers and campus networks.
Compact chassis design with a height of 4 RU improves cabinet space utilization. A single card supports up to 52 non-combo ports and each card provides four fixed 10GE SFP+ ports. This enables the switch to achieve 10GE uplink connections and meet the networking requirements of small and medium-sized core networks or medium-sized network aggregation scenarios with a single card.
CPU Protection Policy (CPP) controls the types and traffic of packets sent to the CPU, preventing CPU usage exceptions.
VSU technology virtualizes multiple physical switches into one logical unit with a single IP address to realize unified management, simplifying O&M. Fast link failover within 50 to 200 milliseconds ensures nonstop transmission of critical services.
Two flash chips for storing boot software achieve hardware-level boot redundancy, avoiding switch boot failures due to a flash chip fault.
1+1 hot standby ensures nonstop switch services.
Four hot-swappable power supplies realize failover within seconds and service continuity during power replacement, ensuring link reliability.
Hareware Specifications |
S7805C |
|||
Interface Specifications |
||||
Power module |
2 |
|||
Supervisor module slot |
2 |
|||
Line card slot |
3 |
|||
Switch fabric module slot |
Built-in |
|||
System Specifications |
||||
Packet forwarding rate |
4,500 Mpps |
|||
System switching capacity |
6 Tbps |
|||
MAC address |
● Number of global MAC addresses EB card: 64,000 DA card: 96,000 (default) and 288,000 (max.) FA card: 80,000 FB card: 96,000 ● Number of static MAC addresses EB card: 4,000 DA card: 10,000 FA card: 4,000 ● FB card: 40,000 |
|||
ARP table |
EB card: 10,000 (default and recommended) DA card: underlay: 75,000; overlay: 0 (default and recommended) FA card: underlay: 30,000; overlay: 0 FB card: underlay: 50,000; overlay: 0 (default and recommended) |
|||
Number of IPv4 unicast routes |
EB card: 12,000 (default and recommended, shared with IPv6 routes) DA card: 12,000 (default and recommended, shared with IPv6 routes) FA card: 12,000 (default and recommended, shared with IPv6 routes) FB card: 134,000 (default and recommended, shared with IPv6 routes) |
|||
Number of IPv4 multicast routes |
EB card: 8,000 DA card: 16,000 FA card: 8,000 FB card: 16,000 |
|||
Number of IPv6 unicast routes |
EB card: 6,000 (shared with IPv4 routes) DA card: 6,000 (shared with IPv4 routes) FA card: 6,000 (shared with IPv4 routes) FB card: 50,000 (shared with IPv4 routes) |
|||
Number of IPv6 multicast routes |
EB card: 4,000 DA card: 8,000 FA card: 4,000 FB card: 8,000 |
|||
Number of ACEs |
● Ingress EB card: 3,500 DA card: 8,000 FA card: 5,000 FB card: 4,500 ● Egress EB card: 1,000 DA card: 1,000 FA card: 1,000 ● FB card: 2,000 |
|||
Number of VSU members |
2 |
|||
Dimensions and Weight |
||||
Dimensions (W x D x H) |
442 mm x 451 mm x 175 mm (17.40 in. x 17.76 in. x 6.89 in., 4 RU) |
|||
Weight (empty chassis and fan modules) |
32.35 kg (71.32 lbs) |
|||
CPU and Storage |
||||
CPU |
● Supervisor module M7805C-CM II: 1.5 GHz quad-core processor ● Service module EB card: 1.0 GHz quad-core processor DA/F card: 1.5 GHz quad-core processor |
|||
Storage |
Flash memory M7805C-CM II: 1 GB EB card: 512 MB DA/F card: 8 GB SDRAM M7805C-CM II: DDRIII 4 GB EB card: DDRIII 1 GB DA card: DDR4 1 GB F card: DDR4 2 GB |
|||
Power and Consumption |
||||
Maximum power consumption |
Chassis RG-S7805C: < 80 W Supervisor module: M7805C-CM II: < 21 W Service module: M7800C-24SFP/12GT4XS-EB: < 85 W M7800C-48GT4XS-EB: < 70 W M7800C-48SFP4XS-EB: < 101 W M7800C-24GT24SFP4XS-EB: < 88 W M7800C-32XS4QXS-DA: < 210 W M7800C-48GT-FA: < 75 W M7800C-48SFP-FA: < 95 W M7800C-48XS-FB: < 160 W M7800C-4CQ-FB: < 120 W M7800C-8CQ-FB: < 130 W |
|||
Maximum output power |
● RG-PA300I-F: 300 W ● RG-PA460I-F: 460 W |
|||
Environment and Reliability |
||||
MTBF |
> 200,000 hours |
|||
Primary Airflow |
● Supervisor module Right-to-left airflow ● Service module Right-to-rear airflow ● System power module Built-in fan modules drawing air outward Front-to-rear airflow |
|||
Operating temperature |
0°C to 50°C (32°F to 122°F) |
|||
Storage temperature |
–40°C to +70°C (–40°F to +158°F) |
|||
Operating humidity |
10% to 90% RH (non-condensing) |
|||
Storage humidity |
5% to 95% RH (non-condensing) |
|||
Operating altitude |
–500 m to +5,000 m (–1640.42 ft. to +16404.20 ft.) |
|||
Operating noise |
55.9 dB at the temperature of 35°C (95°F) 73.4 dB at the temperature of 50°C (122°F) |
|||
Interface surge protection |
All electrical ports support 4 kV surge protection in common mode or 1 kV surge protection in differential mode. |
Reviews (0)